High Frequency Anaesthesia Machines for Hospital BJP-850A
    Publish time 2025-09-03 21:36    
High Frequency Anaesthesia Machines for Hospital BJP-850A

BJP-850A Medical Color LCD Screen Trolley Anesthesia Machine

This BJP-850A Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.

Power On Self Test

The automatic conversion for standby power while AC power outage, keep working not less than 1 hour.


Promoting Excellence Through Design

Built from nonhazardous environmentally friendly material, the precisely constructed and elegantly designed Jinling 850 Adv. provides an ergonomic and easily movable anesthesia machine that requires only the bare minimum of operating space.

Physical specifications

Screen

8.4 / 10.4 inch LCD Display Screen

Suitable

Adult & Child

Mode

pneumatically powered and electrically controlled system

Working Mode

Closed; Semi-Closed; Semi-Open

Circuit

Breathing circuit integrated standards

Flowmeters

5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min

Trolley

Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

Drawer unit

TWO drawers totally extractable

Technical Specifications

Gas requirement

Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa; NO2: 0.32 MPa to 0.6 MPa.

safety valve

<12.5 kPa

Respiratory Rate

1~99bpm

oxygen concentration in the mixed gas N2O/O2

> 21%

Oxygen Flush

25~75 L/min

Modes of ventilation

A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, SIGH, PEEP, MANUAL

PEEP

0 ~ 20 hPa

Ptr

-10 ~ 20 hPa

IMV frequency

1 ~ 20 bpm

I/E Ratio

8:1 ~ 1:10, Has the inverse ratio ventilation

Tidal Volume

0 ~ 1500 ML

Inspiratory Plateau

0~1s

O2 Concentration

21%~100%

Sigh

one deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point

Maximum safety pressure

≤ 12.5 kPa

Pressure limit range

0 ~ 6.0 kPa

Airway pressure alarm: Audible and visual and with yellow and red color indicating

Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa

±0.2 kPa

Tidal volume alarm: Audible and visual and with yellow and red color indicating

upper alarm: 50 to 2000ml, lower alarm: 0~1800ml

Oxygen concentration alarm: Audible and visual and with yellow and red color indicating

upper alarm: 21% ~100%; lower alarm:10%~80%

Power Supply Alarm

Ac/dc power supply are after failing to send out alarm immediately

Alarm Time: keep >120s

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.

Safty & Alarm

Oxygen Alarm

It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa

Ventilation Volume Alarm

Lower: 0~12L/Min; Up: 18L/ Min

Power Alarm

It Alrmas while AC and DC supply failure; Keep alraming time: >120s

Air Tract Pressure Alarm

Lower: 0.2kPa ~5.0 kPa; Up: 0.3kPa ~ 6.0kPa